An industrial air shower is a self-contained personnel decontamination chamber positioned at cleanroom entry points. It produces high velocity HEPA filtered air jets that physically dislodge and trap surface borne contaminants such as dust, hair and fibres from workers and equipment prior to entry into regulated areas. More than 80% of cleanroom contamination is caused by human activity, according to ISO 14644-1. The industrial air shower is a physical buffer zone that significantly lowers particle carry-over, helping facilities fulfil more severe cleanliness categories and food safety or pharmaceutical GMP criteria.
An air shower for people is a tunnel with high-speed nozzles on both sides of the walls and roof. When a person or cart comes into the room, both doors close at the same time and filtered, pressurized airflow starts to flow. The particles that are conveyed are then captured by return air grilles and pushed to pass through the HEPA filters. The whole thing takes place in 10 to 30 seconds. Studies show that 10-15 seconds is enough to remove over 90% of surface particles, not slowing down the process.
Three separate systems must work together for a sterile air shower to be effective. The basic model of the Homey Wonbond includes a fan motor of 1.1 kW, which delivers air to 12 precisely adjustable nozzles with air speeds of 305 m/s. HEPA filter module eliminates 99.9 % of particles ≥0.5 μm. Cycle times from 0 to 99 seconds can be set by operators using a digital control panel with LEDs. Voice prompts take each user through the required actions automatically.
Both doors can't open at the same time because of the magnetic locking system. This makes a real airlock. Standard safety requirements include emergency stop buttons and circuits that protect against too much power. This interlock logic is a recorded compliance point inspectors specifically check during site reviews for food processing plants that want to get FSSC 22000 or BRC certification.
Particle counts in ISO Class 6–8 rooms rise quickly when people don't do enough to clean up after themselves. A properly set up air shower system keeps the area clean between shifts, which lowers the number of rejects and the cost of repairs. According to BRC Global Standard audit documentation from multiple sites, food manufacturers who put in place personnel air showers saw a measurable drop in the number of microbes on the surface at zone transition points.
The standard industrial air shower industrial-grade unit from Homey Wonbond comes with the following checked features:
At 0.3 μm, HEPA filters get rid of 99.97% of particles, and at 0.12 μm, ULPA filters get rid of 99.9995%. HEPA is the standard for ISO Class 7–8 environments used in food processing and pharmaceuticals. It is only used in semiconductor factories or ISO Class 5–6 rooms where particle counts below 0.1 μm are important. Most of the time, HEPA-grade filtration in a dual-door air shower is enough for FSSC 22000 and BRC audits.
Airlocks control the difference in air pressure between zones, but they don't clean people of particles. Procedures are very important in dressing rooms; if a worker forgets a step, contamination can get in without being stopped. An air shower is a mechanical way to clean that can be used over and over again and doesn't depend on people following the instructions. When dozens of workers change shifts at the same time in high-throughput food plants, the air shower's automated cycle is more reliable than any human routine.
Air showers made by Terra Universal and Cleanroom Technology are used a lot in medicinal plants in North America. Envair's main market is the life sciences market in Europe. These brands have good names, but custom designs often take 8–12 weeks to make, and project managers who work with cleanroom engineering firms can't always get factory-direct prices. Homey Wonbond can ship custom units in 14 business days at factory-direct prices, and all of their shipments are backed by CE certification and ISO 9001 quality records.
Air shower units with air dryers can aid in some cleanrooms, notably those that operate with hygroscopic powders or are located in damp locations. Dryer-integrated kinds cost more up front, but they protect garments from getting wet, which can carry germ risk into temperature-controlled areas. Standard types that don't have dryers can handle most food processing and tech manufacturing tasks and cost less to buy at first.
There's more to choosing a cleanroom decontamination unit than just looking at a price list. Before making a decision about a seller, buying managers should look at these main factors:
These factors for an industrial air shower will directly tell you if the machine you buy will still work reliably after two years, or if you will have to go looking for replacement parts with no help behind them.
Food industry QA teams seeking FSSC 22000 or BRC certification must demonstrate that their air shower meets the ISO 14644 cleanroom classification requirements. Before you sign a purchase order, request test reports with recorded airflow speed and particle counts. Pharmaceutical procurement teams also need to ensure that the unit's materials can be cleaned using their chemical cleaners, and the vendor preserves production records that can be traced.
Professional installation starts with making sure the floor is level. If the base isn't level, the door seal gaps open up, which makes the airlock less effective. The air shower should be built in the flow of the cleanroom so that people cannot get past it to get to the controlled area. Before the delivery, the power supply must be checked by an electrician. It must be 380 V/50 Hz.
Place people in the middle of the chamber and rotate them slowly once with their arms up so air moves over all of their bodies. A laminated process card in the room and a short training session for new staff members takes less than 30 minutes and makes decontamination substantially more consistent.
Most buyers worry about having to update the HEPA filter. Homey Wonbond sells replacement filters directly, and our customer service team offers a service to remember you to do regular upkeep. Every month, pre-filters in food settings with a lot of particles should be checked. If the pre-filter gets clogged, the nozzle velocity drops below 18 m/s, which lowers the effectiveness of decontamination even before the HEPA layer is affected.
An industrial air shower is one of the easiest ways to protect the purity of the cleanroom at the door, which is where it is most at risk. When properly designed, installed, and kept, it gets rid of most of the particle contamination that people bring in, which helps with both ISO 14644 compliance and food safety certification audits. Nozzle speed, filter grade, chamber size, and long-term service availability are the most important factors. If you take care of those four things, the unit will work well for years to come.
In standard food processing conditions, HEPA filters last 12–24 months. Pre-filters should be cleaned or replaced every 1–3 months. Facilities with unusually high ambient dust loads may need more frequent service intervals.
Yes. The standard Homey Wonbond model holds 4–5 persons. Custom configurations support 6–10 persons and are available with modified external and internal dimensions to fit your specific corridor width.
Typical industrial air shower units operate between 65–75 dB during the blower cycle. This is comparable to normal office HVAC background noise and does not require hearing protection under standard OSHA guidelines.
Your cleanroom entry point should have a reliable solution backed by 18 years of experience with biosafety equipment. Homey Wonbond's industrial air shower line sends CE-certified, SUS 304-built units at factory-direct prices. It takes 14 business days to make custom setups. Get in touch with our team right away to get a competitive quote and a review of your specifications that are unique to your location. To get a quote, email us at frank@hmwbcleaning.com or go to hmwbcleaning.com.
1. ISO 14644-1:2015 — Cleanrooms and Associated Controlled Environments: Classification of Air Cleanliness by Particle Concentration. International Organization for Standardization, 2015.
2. BRC Global Standard for Food Safety, Issue 9. British Retail Consortium, 2022.
3. FSSC 22000 — Food Safety System Certification Scheme, Version 6. Foundation FSSC 22000, 2023.
4. Austin, P.R., & Timmerman, S.W. — Design and Operation of Clean Rooms. Business News Publishing, 1965 (revised industry reference edition).
5. ISO 14644-3:2019 — Cleanrooms and Associated Controlled Environments: Test Methods. International Organization for Standardization, 2019.
6. Whyte, W. — Cleanroom Technology: Fundamentals of Design, Testing and Operation, 2nd Edition. Wiley, 2010.
Learn about our latest products and discounts through SMS or email